Russian

VT0001 Controller


 

DESCRIPTION

 

Designed to be used as a Slot 0 Controller or a VXIbus Resource Manager under

an external host computer (IBM PC AT) control over GPIB and or RS 232 interface bus.

 

SPECIFICATIONS

 

The Controller system functions:

- А16/А24 master providing D16, D08(EO), RMW data transmission;

- А16, D16 slave;

- BR3 line parity request;

- programmable interrupt handler;

- PRI bus arbiter;

- VXIbus timeout (³100 ms);

- 16 MHz system clock driver;

- 10 MHz TTL clock driver;

- MODID lines control and reading of their states;

- TTLRG0TTLTRG7, ECLTRGO, ECLTRG1, trigger line control, reading of their state, detection of positive and negative drops in trigger lines;

- buffering of triggers applied from any TTLTRG(x) lined to input connector TRIGGERING;

- transmission of the signal from TRIGGERIN connector to any TTLTRG(x) line.

 

Max. data transmission rate:

over the GPIB:   40 kb/s;

over RS 232: 2400 baud/s.

 

The Controller is a C-size, 1-slot VXI Commander with P1 and P2 connectors.

The VT0001 Controller command library and their description is supplied on a floppy disk.

 

Power:

 

Voltage, V

Current consumption, А

Dynamic value, ID

Peak value, IP

 

 

 

+5

0.3

0.25

-2

0.3

0.25

+12

0.1

0.07

-12

0.20

0.15

 

Cooling at 10 °С overheating:

DP mm H2O: 0.4 mm

air flow: 1.75 l/s

 

Operating temperature range: from-10 to +50 °С

Weight: 1.5 kg